不锈钢电缆桥架距地高度设为多少合适?

  1、山东电缆桥架搭建的时候一定要确定好方向,各个设备都要方便维护,以免出现故障无法维修,造成更大的危害。

  1, cable bridge construction, must make sure the direction, each device should be convenient maintenance, so as to avoid failure, can not repair, cause greater harm.

  2、在安装之前需要先检查下不锈钢电缆桥架的外观,看下表面是不是平整光滑,不要出现掉漆的情况,同时看下钢材之间的焊接是不是结实。

  2, before installing, you need to check the appearance of the stainless steel cable tray, see if the surface is smooth and smooth, do not paint off, and see whether the welding between the steel is firm or not.

  3、桥架的安装不管是采用固定的还是悬挂的,都一定要看好各个部件之间连接的是不是紧固,不能有松动的现象,保证施工。

  3, the installation of the bridge, whether it is fixed or suspended, must be optimistic about the connection between the various components, is not tight, can not be loose phenomenon, to ensure safety in construction.

  4、电缆桥架的安装要确定好具体的位置,同时各个层之间要留距离,保证可以正常的散热和维护,同时如果有其他的管道平行着,要保证规定的距离,避免互相干扰。

  4, the installation of cable tray to determine the specific location, at the same time, each layer must be left between the distance, can guarantee the normal cooling and maintenance at the same time, if there are other parallel pipeline, to ensure that the provisions of the distance, to avoid mutual interference.
山东电缆桥架

  热镀锌的电缆桥架镀层表面应均匀,无过烧、挂灰、局部未镀锌等缺陷。静电喷塑应平整、光滑、均匀、不起皮,无气泡、水泡桥架本身应平整,无扭曲变形,内壁应光滑、无毛刺桥架焊缝表面应均匀,不得有漏焊、裂纹、烧穿等缺陷。

  The surface of the cable tray of hot galvanized steel wire should be even, without excessive burning, hanging dust or local galvanization. Electrostatic spray should be flat, smooth, uniform, no peeling, no bubble, blister tray itself should be smooth, without distortion, the wall should be smooth, no burr bridge weld surface should be uniform, no leakage of welding, crack, burn and other defects.

  桥架水平敷设时,距地高度一般不宜低于2.5m。桥架多层敷设时,为了散热、维护以及防干扰的需要,桥架层间应留有一定的距离电缆桥架在与各种管道平行敷设时,其净距应符合有关的规定。

  When the bridge is horizontally laid, the distance from the ground should not be less than 2.5m. When the bridge is covered with multiple layers, the distance between the bridge layers should be kept a certain distance for the purpose of heat dissipation, maintenance and interference prevention. The bridge spacing shall be in line with the relevant provisions when parallel with all kinds of pipelines.

  本文的精彩内容来自山东电缆桥架详细内容请点击我们的网站:http://www.sdhangfeng.com/谢谢您的到来!

  The exciting content of this article comes from the Shandong cable tray. Please click on our official website: http://www.sdhangfeng.com/, thank you for coming!

 