电缆桥架厂家如何处理弹性缝问题
镀锌电缆桥架厂家弹性缝是沿建筑物或构筑物施工缝方向在适当位置设置的一种构造裂缝,以防止因气候、温度的变化而造成建筑构件的开裂或损坏。那么电缆桥架厂家弹性接头的处理方法是什么呢?
The elastic joint of galvanized cable bridge manufacturer is a kind of structural crack set at an appropriate position along the construction joint direction of buildings or structures to prevent cracking or damage of building components due to climate and temperature changes. What is the treatment method of the elastic joint of the cable bridge manufacturer?
如果桥梁一侧有长直线段穿过弹性缝,应大于30m,或者弹性缝两侧直线段加起来有30m。电缆桥架厂家当弹性缝处桥下有满意的空间时,桥可以断开。电缆桥架厂家断开间距B应大于建筑物弹性缝的宽度L,电缆桥架厂家并应保证所有电缆能沿弹性缝自由弹性而不被损坏,并满足电缆一起伸缩时较小弯曲半径R的要求。
If there is a long straight section passing through the elastic joint on one side of the bridge, it shall be more than 30m, or the straight sections on both sides of the elastic joint add up to 30m. The cable bridge manufacturer can disconnect the bridge when there is a satisfactory space under the bridge at the elastic joint. The disconnection distance b of the cable tray manufacturer shall be greater than the width l of the elastic joint of the building. The cable tray manufacturer shall ensure that all cables can be freely elastic along the elastic joint without being damaged, and meet the requirements of the smaller bending radius r when the cables expand and contract together.
如果弹性接头处镀锌电缆槽下没有足够的空间,加宽的直通应设置在弹性接头附近,加宽直通的规格应能留有足够的电缆弹性余量(大于L),并能满足一起弹性时电缆较小的缠绕半径。电缆桥架厂家弹性缝加宽直通两侧之间的间隙b可以略大于弹性缝宽度L..当弹性缝横向无空间,无法安装加宽直通时,可适当向弹性缝两侧偏移。电缆桥架厂家当每侧一个加宽直通不能满足电缆桥架厂家足够弹性和较小缠绕半径的要求时,可在弹性缝两侧安装两个对称连接的加宽直通。弹性缝两侧的桥间距b仍略大于l。
If there is not enough space under the galvanized cable tray at the elastic joint, the widened straight shall be set near the elastic joint. The specification of the widened straight shall be able to leave enough cable elastic allowance (greater than l) and meet the smaller winding radius of the cable when it is elastic together. The gap B between the two sides of the widened straight through of the elastic joint of the cable bridge manufacturer can be slightly larger than the width l of the elastic joint. When there is no space in the transverse direction of the elastic joint and the widened straight through cannot be installed, it can be appropriately offset to both sides of the elastic joint. When the cable tray manufacturer fails to meet the requirements of the cable tray manufacturer for sufficient elasticity and small winding radius, two symmetrically connected widened straight pipes can be installed on both sides of the elastic joint. The bridge spacing B on both sides of the elastic joint is still slightly larger than L.
以上就是为大家介绍的有关山东电缆桥架的详细的介绍,希望对您有所帮助.如果您有什么疑问的话,欢迎联系我们.我们将以的态度,为您提供服务http://www.sdhangfeng.com
The above is the detailed introduction of Shandong cable bridge, which is helpful to you. If you have any questions, please contact us. We will provide you with services with a professional attitude http://www.sdhangfeng.com