配电箱安装的14个禁忌:

配电箱是现代家庭和企业中必不可少的电力分配设备,它的安装和使用对于电力系统的和稳定性关重要。然而,在配电箱的安装和使用过程中,由于意识不足或者不了解相关规定,可能会导致电气事故的发生。因此,在安装和使用配电箱时,需要遵守一些禁忌,以确保和可靠性。
Distribution boxes are essential power distribution equipment in modern homes and businesses, and their installation and use are crucial for the safety and stability of the power system. However, during the installation and use of the distribution box, due to insufficient safety awareness or ignorance of relevant regulations, Electrical safety accidents may occur. Therefore, when installing and using distribution boxes, it is necessary to follow some taboos to ensure safety and reliability.
下面山东电缆桥架厂家来讲讲配电箱安装14个禁忌:
Next, the manufacturer of cable tray in Shandong will talk about 14 taboos for the installation of distribution box:
1、配电箱内应装设专用的漏电保护开关。
1. A dedicated leakage protection switch should be installed inside the distribution box.
2、在进入总配电箱的电缆入口处,应装置额定电流不低于10a的漏电保护开关。
2. At the cable inlet of the main distribution box, a leakage protection switch with a rated current of not less than 10a should be installed.
3、同一回路控制相和主变压器负荷侧的总漏电保护开关不应装在一处。
3. The total leakage protection switch on the control phase and load side of the main transformer in the same circuit should not be installed together.
4、配电箱内的照明和动力电缆宜集中敷设,不宜穿管敷设;动力电缆宜沿管道敷设,照明电缆可采用金属管(或带屏蔽层的软管)埋地敷设。
4. The lighting and power cables inside the distribution box should be laid in a centralized manner and should not be laid through pipes; Power cables should be laid along pipelines, while lighting cables can be buried in metal pipes (or hoses with shielding layers).
山东电缆桥架
5、配电箱内不宜安装过多的仪表,以免增加接线点,造成线路紊乱。
5. It is not advisable to install too many instruments in the distribution box to avoid adding wiring points and causing circuit disorder.
6、总配电箱内一般不宜装设超过三个计量表。
6. It is generally not advisable to install more than three measuring meters in the main distribution box.
7、配电箱内所有电器设备的安装均应有固定基础。
7. All electrical equipment in the distribution box should be installed with a fixed foundation.
8、总配电箱及分段配电箱内的所有电线电缆应选用铜芯截面不小于6mm2的多股软导线;严禁使用铝绞线。
8. All wires and cables in the main distribution box and segmented distribution box should be multi stranded flexible conductors with a copper core cross-section of not less than 6mm2; The use of aluminum stranded wires is strictly prohibited.
9、总配电箱各分配电箱的电源进线,采用三条电缆从总配电箱经分段开关连接。
9. The power incoming lines from the main distribution box to each distribution box are connected by three cables through segmented switches from the main distribution box.
10、每台用电设备都有专用的供电开关。
10. Each electrical device has a dedicated power supply switch.
11、总配电箱内应设置专用的接地保护和重复接地装置。
11. Special grounding protection and repeated grounding devices should be installed inside the main distribution box.
12、总配电箱应有可靠的防雨措施,严禁渗水漏电。
12. The main distribution box should have reliable rainproof measures, and water leakage and leakage are strictly prohibited.
13、禁止私自改装配电箱和拆卸配电箱的保护装置。
13. It is prohibited to modify the distribution box and dismantle the protective device of the distribution box without permission.
14、禁止在配电箱周围堆放危险品和危险物品。
14. It is prohibited to stack dangerous goods and materials around the distribution box.
以上14个禁忌是在配电箱安装和使用过程中需要严格遵守的。在安装和使用配电箱时,要多多关注其中的事项,更多事项就来我们网站http://www.sdhangfeng.com咨询!
The above 14 taboos need to be strictly followed during the installation and use of distribution boxes. When installing and using distribution boxes, it is important to pay more attention to the issues involved. For more information, please visit our website http://www.sdhangfeng.com consulting service
 