电缆桥架的设计要注意什么?
1、设计人员自己熟悉规范,保证电缆桥架占有的容积符合要求,一般以40%为好。尽量不要超过规定的密度,以免加速电缆绝缘老化,否则需要加大电缆,增加投资。
1. The designers themselves are familiar with the specifications to ensure that the volume occupied by the cable tray meets the requirements, generally 40% is better. Try not to exceed the specified density to avoid accelerating the aging of cable insulation, otherwise it is necessary to increase the cable and increase investment.
2、电缆、电线不能在同一线槽内敷设,原因:二种线型的允许温度不一样,电线的绝缘层比较薄容易被电缆拉伤。电线的机械强度不够,容易给电缆压断。
2. Cables and wires cannot be laid in the same trunking. The reason is that the allowable temperature of the two types of wire is different, and the insulation layer of the wire is relatively thin, which is easy to be pulled by the cable. The mechanical strength of the wire is not enough, which is easy to break the cable.
电缆桥架
Cable tray
3、不同类型的电缆也不应在同一线槽内敷设,主要是运行温度不一致,如VV系列65度,YJY系列90度。若同一线槽敷设,耐温低的电缆会加速绝缘老化。


3. Different types of cables should not be laid in the same trunking. The main reason is that the operating temperature is different, such as 65 degrees for VV series and 90 degrees for YJY series. If laid in the same trunking, the cable with low temperature resistance will accelerate insulation aging.
4、电缆桥架布线时,线槽内敷设的电缆容量应根据同一线槽内电缆数量、敷设环境温度等综合考虑,一般按电缆额定容量的60%-80%考虑,塑料线槽因散热不好可按50-70%考虑。
4. During cable tray wiring, the cable capacity laid in the trunking shall be considered comprehensively according to the number of cables in the same trunking, the laying environment temperature, etc., generally 60% - 80% of the rated capacity of the cable, and 50-70% of the plastic trunking due to poor heat dissipation.
5、防火桥架由于其结构特殊(内部增加防火棉、防火板),内部空间比普通桥架小,选用时注意电缆占有。
5. Due to its special structure (adding fireproof cotton and fireproof board inside), the internal space of the fireproof bridge is smaller than that of the ordinary bridge. Pay attention to the floor area ratio of the cable when selecting.
6、防火桥架由于其结构特殊(内部增加防火棉、防火板),散热条件差, 电缆载流量可按电缆额定载流量的40%-60%考虑。
6. Due to its special structure (adding fireproof cotton and fireproof board inside) and poor heat dissipation conditions, the cable carrying capacity can be considered as 40% - 60% of the rated carrying capacity of the cable.
7、防火桥架由于其结构特殊(内部增加防火棉、防火板),自重比普通桥架重,设计固定支吊架时不能按照钢制桥架设计规范中的标准间距设置,应加大密度,建议采用1 -1.5米间距,具体视设计的桥架大小定。
7. Due to its special structure (adding fireproof cotton and fireproof board inside), the dead weight of the fireproof bridge is heavier than that of the ordinary bridge. When designing the fixed supports and hangers, they cannot be set according to the standard spacing in the steel bridge design specification, and the density should be increased. It is recommended to use a spacing of 1-1.5m, depending on the size of the designed bridge.
有了济南电缆桥架上面的小总结,希望对广大客户有所帮助,如果有什么不理解的或者寻求帮助的请点击我们的网站:https://www.sdhangfeng.com或者来电咨询,我们会尽全力为您解决
With the summary above Jinan cable bridge, I hope it can help our customers. If you have any questions or need help, please click our website: https://www.sdhangfeng.com Or call for consultation, and we will do our best to solve it for you
上一篇:电缆桥架的选择要注意什么?
下一篇:铝合金电缆桥架的使用性能介绍
下一篇:铝合金电缆桥架的使用性能介绍
相关文章 / Recommended news
- 山东电缆桥架屋顶吊装:配件清单+标准化流程,新手也能零失误
- 济南电缆桥架安装:200多斤600×200桥架,这样吊装又
- 山东电缆桥架定制:耐火板与防火型的核心区别,一文读懂避坑指南
- 济南电缆桥架选型误区:100×100规格加隔板难?航丰的方案破解施工难题
- 山东电缆桥架避坑!贯穿孔成火灾“隐形通道”?3步防火实操筑牢防线
- 济南电缆桥架铺设踩坑,层数、根数、限制,规范不看必返工
- 山东电缆桥架(镀锌款)接地线误区,接错必返工,规范要点一文说清
- 济南电缆桥架线缆捆扎错了=埋隐患,4种规范方法,施工必看
- 山东不锈钢桥架现场打孔避坑!4步标准流程,90%施工方少走弯路不损桥架
- 山东电缆桥架选型封神指南!记住3句话,70%工程方避开选型陷阱不花冤枉钱
阳极氧化铝合金桥架
托盘式电缆桥架
梯式电缆桥架
梯式不锈钢电缆桥架
深灰色金属防火电缆桥架