保证电缆桥架质量的措施有哪些?
1、施工前组织施工人员进行技术交底工作,并做好交底会签,将责任落实到每一个操作工人。
1. Organize the construction personnel to carry out technical submission work before construction, and do a good job of submission meeting signature, and implement the responsibility to every operator.
2、材料进入施工现场,必须按产品标准及规定程序进行检查验收,并做好记录及材料报验工作,严禁不合格产品用于工程中。
2. When materials enter the construction site, they must be inspected and accepted according to the product standards and prescribed procedures, and record and material inspection should be done well. It is strictly forbidden to use unqualified products in engineering.
3、熟悉设计图纸,理解并掌握设计意图,发现问题及时联系建设、监理、设计单位,做好图纸会审工作。
3. Familiar with design drawings, understand and master design intentions, contact construction, supervision and design units when problems are found, and do a good job of drawing auditing.
4、桥架的运输和堆放应附合有关规定,注意防潮防污。
4. Transportation and stacking of bridge frames should be accompanied by relevant regulations, and attention should be paid to moisture-proof and pollution-proof.
5、使用高凳时,注意不要碰坏建筑物的墙面及门窗。
5. When using high benches, be careful not to touch the walls and doors and windows of buildings.
6、严格按标准、规范、规程及设计图纸组织施工,施工中应与水暖、土建密切配合,施工质量必须符合现行标准及规范规定。
6. Construction should be organized in strict accordance with standards, norms, regulations and design drawings. Construction should be closely coordinated with plumbing and civil engineering specialties. Construction quality must conform to current standards and norms.
7、施工过程中及时做好中间检查工作,发现问题及时解决,施工完后,做好自检工作,自检通过后再通知监理单位工程师进行隐蔽前验收工作。
7. In the process of construction, do a good job of intermediate inspection, find problems and solve them in time. After completion of construction, do a good job of self-inspection, and inform the professional engineers of supervision units to check and accept the work before concealment.
8、技术资料应随工程进度及时报验、整理,按系统分类、归档,各种原始检测记录应真实、准确、齐全。
8. Technical data should be submitted and collated in time with the progress of the project, classified and filed according to the system, and all kinds of original testing records should be true, accurate and complete.
9、对于易发生受污生部位(如机房、电气竖井等)的桥架,应注意检查,发现后及时处理,补刷防锈漆。
9. For bridges that are liable to contamination (such as machine rooms, electrical shafts, etc.), attention should be paid to inspection, timely treatment after discovery, and repairing rust-proof paint.
本文精彩内容由电缆桥架整理提供!希望通过小编的介绍对大家有所帮助,我们的官网是:http://www.sdhangfeng.com多谢大家的阅读观看!
The wonderful content of this article is provided by the cable bridge arrangement! Hope to help you through the introduction of Xiaobian, our official website is: http://www.sdhangfeng.com Thank you for reading and watching!